Gas pressure ports on Flare Linear Frameless fireplaces
See below for Flare modern fireplace GV60 gas value, inlet and outlet test ports. All of Flare frameless fireplace share the same gas valve system . Overall port diagram
See below for Flare modern fireplace GV60 gas value, inlet and outlet test ports. All of Flare frameless fireplace share the same gas valve system . Overall port diagram
For best results, Flare recommends ordering your fireplace with the correct gas type. Understanding circumstances can change at each jobsite, instructions for swapping the components on your Flare Fireplace are included below. Conversion swaps available for both NG to LP and LP to NG. It is always imperative to leak test all gas connections after
For Fireplaces sized 30" up to 70" - a Minimum of 3' rise off the top of the fireplace is required before any elbow For Fireplaces sized 80" up to 100" - a Minimum of 6' rise off the top of the fireplace is required before any elbow Installation Manual (pgs 60-69) for specific venting